Large metal process tank inside a production building
Storage and process tanks

Tank Heating

Methods to heat and hold tank contents: direct immersion, over-the-side, external circulation or surface heating.

Tank heating with a flanged immersion heater and temperature control Controller Sensor Flanged heater Insulation

Schematic illustration drawn for ECC, not to scale.

01Product description

A tank can be heated by direct immersion heaters, over-the-side heaters, a side-arm or external circulation heater, or by heaters clamped to the outside of the tank. The choice depends on the process, available space inside and outside the tank, economy and maintenance.

02Operating principle

The heater supplies the energy to raise the contents to temperature and then replaces the heat lost through the walls, the liquid surface and connected piping. Insulation and covers reduce the holding load.

03Industrial applications

  • Water storage and freeze protection
  • Oil storage and viscosity control
  • Chemical and plating tanks
  • Food-grade liquids (with appropriate materials)

04Technical characteristics

  • Choice of heating method by tank geometry and access
  • Over-the-side heaters for open tanks that cannot be drilled
  • Temperature control and low-level protection
  • Insulation and covers to reduce losses

05Advantages

  • Method matched to the tank and the maintenance needs
  • Lower energy use when losses are controlled

06Selection variables

  • Medium being heated, its chemistry and its viscosity across the temperature range
  • Required power (kW) for heat-up and for holding temperature, including heat losses
  • Operating temperature and maximum allowable sheath temperature
  • Allowable watt density for the medium and flow condition
  • Sheath material compatible with the medium and the temperature
  • Supply voltage, number of phases and circuit arrangement
  • Terminal enclosure rating for the installation area (general purpose, moisture-resistant or hazardous location)
  • Temperature control and over-temperature protection
  • Tank volume, geometry and access for installation
  • Whether the tank is open or closed, and whether it can be drilled

07Installation considerations

  • Over-the-side heaters: keep the heated section near the bottom and below the minimum level.
  • Provide a low-level cutoff on any direct-immersion arrangement.
  • Insulate the tank and cover the liquid surface where possible; surface losses rise quickly with temperature.

08Technical information

Once the tank is at temperature, the heater only replaces what is lost. Losses through an insulated wall can be estimated by conduction.

Q (Btu/h) = k × A × ΔT ÷ x
P (W) = Q ÷ 3.412

k = thermal conductivity of the insulation (Btu·in/h·ft²·°F) · A = wall area (ft²) · ΔT = liquid temperature − ambient (°F) · x = insulation thickness (in).

Worked example

A tank with 60 ft² of wall covered with 2 in of insulation (k assumed at 0.30), holding liquid at 160 °F with 70 °F ambient:

Q = 0.30 × 60 × 90 ÷ 2 = 810 Btu/h
P = 810 ÷ 3.412 = 237 W to hold temperature through the walls

Open liquid surfaces, uninsulated bottoms, fittings and piping usually lose much more than an insulated wall and must be added. Use automatic temperature control and a low-level cutoff.

Request information on tank heating

Share your application data; we will reply with the next steps and a quotation where possible.