Immersion Heaters
Heating elements placed directly in the liquid, transferring heat by conduction and convection into the medium.
Hairpin elements welded or brazed to a pipe flange, bolted to a matching nozzle on the tank or vessel.
Schematic illustration drawn for ECC, not to scale.
A flanged immersion heater consists of hairpin tubular elements welded or brazed to a flange, with a terminal enclosure on the outside. The flange bolts to a matching flanged nozzle on a tank or pressure vessel. Because the flange can carry many elements, this design covers higher power ratings than threaded heaters and is the core of most circulation heaters.
Each element converts electrical energy into heat in its resistance coil; the heat flows through the insulation and sheath into the liquid. The flange seals the opening and supports the element bundle, and the terminal enclosure houses the electrical connections and, when specified, thermostats or thermocouple connections.
Flanged heaters are usually sized from the energy needed to bring a tank to temperature in a given time, and then checked for watt density.
cp = specific heat · ΔT = temperature rise · SF = safety factor · t = heat-up time (h) · 3,412 Btu = 1 kWh.
Heat 500 US gal of water from 60 °F to 140 °F in 2 hours, with a 1.2 safety factor:
Watt density check with 6 hairpin elements of 0.475 in and 60 in of heated length per leg:
The result falls inside the typical range for water (45–75 W/in²). Heat losses from the tank are evaluated separately and added to the power.
Share your application data; we will reply with the next steps and a quotation where possible.
Heating elements placed directly in the liquid, transferring heat by conduction and convection into the medium.
Elements brazed or welded into a threaded hex plug that screws into a tank fitting or half coupling.
A flanged heater installed in an insulated vessel through which the fluid is pumped, heating it in-line.