Immersion Heaters
Heating elements placed directly in the liquid, transferring heat by conduction and convection into the medium.
A flanged heater installed in an insulated vessel through which the fluid is pumped, heating it in-line.
Schematic illustration drawn for ECC, not to scale.
A circulation heater is a flanged immersion heater mounted inside a vessel with inlet and outlet connections. The fluid is pumped through the vessel and heated as it flows past the elements. This allows indirect heating of a tank, or direct heating of a process stream, without placing elements in the tank itself.
Forced flow across the elements increases heat transfer compared with still liquid, so the heater can be smaller for the same duty. Flow rate, inlet temperature and outlet temperature define the power required; a controller modulates the heater to hold the outlet temperature.
A circulation heater is sized from the flow rate and the temperature rise of the fluid passing through it.
SG = specific gravity of the fluid (water = 1.0).
10 gpm of water heated from 60 °F to 120 °F:
20 gpm of oil (SG 0.87, cp 0.50 Btu/lb·°F) heated by 50 °F:
Add a safety factor and the losses of the piping. For thermal fluids, guidance from fluid suppliers is about 20–22 W/in² with fully turbulent flow and 10–12 W/in² without circulation.
Share your application data; we will reply with the next steps and a quotation where possible.
Heating elements placed directly in the liquid, transferring heat by conduction and convection into the medium.
Hairpin elements welded or brazed to a pipe flange, bolted to a matching nozzle on the tank or vessel.
Elements brazed or welded into a threaded hex plug that screws into a tank fitting or half coupling.